Magnesium Aluminum Silicate USP NF or Magnesium Aluminum Metasilicate Manufacturers, with SDS GHS MSDS Sheet

Supplier, Manufacturer, Exporter of Magnesium Aluminum Silicateor Magnesium Aluminum Metasilicate, Muby Chemicals of Mubychem Group, established in 1976, is the original manufacturers of Specialty Chemicals, Pharmaceutical Excipient, Fragrance Food & Flavor chemicals, Reagent Grade Chemicals, Shale Gas Fracturing Chemicals in India. Mubychem Group has several manufacturing facilities spread across Western India and world wide contacts and toll manufacturers. We are exporting globally to countries like USA, Canada, Europe, UAE, South Africa, Tanzania, Kenya, Egypt, Nigeria, Cameroon, Uganda, Turkey, Mexico, Brazil, Chile, Argentina, Dubai, Korea, Vietnam, Thailand, Malaysia, Indonesia, Australia, China, Germany, France, Italy, Portugal etc.

The products are offered as per required specifications and in correct shape and size in mm or meshs or microns as specified by the buyer.

The participating units have one or more accreditations like FDA - cGMP and GLP approval, ISO-9001 Certified, "REACH" Registered, ISO-14001, ISO/IEC 17025, ISO-22000, FSSC 22000, ISO 45001, Kosher Certified, Halal Certified, HACCP, FSSAI. We offer Commercial Pure & IP BP EP Ph Eur USP NF JP FCC Food Grade Analytical Reagent Grades of Chemicals
ISO9001 ISO IEC 17025 ISO14001 ISO 45001 ISO 22000 HACCP FSSC22000 HACCP GMP Good Laboratory fssai HACCP halal jkkosher allergen free Gluten Free Reach

Bookmark this Web Site -- or -- Email This Page Info to a Colleague or Yourself

Search our website here:

Home --------- Contact

Chemical Products

Export to USA UAE Europe Africa Tanzania Kenya Egypt Turkey Jumbo Packing; Exports to USA UAE Europe Africa Tanzania Kenya Uganda Egypt Turkey Brazil Chile Argentina Dubai etc. Packing Palletized and Shrink Wrapped; 25kg or 50kg or 55 lbs HDPE laminated bags with an extra HMHDP liner Drum Packing for better transportation Drum Packing & Palletized Liquid Chemical Export Import Air Freighting

Magnesium Aluminum Silicate or Magnesium Aluminum Metasilicate: CAS Number: 12511-31-8 or 1327-43-1 or 12199-37-0, EINECS EC Number: 215-478-8, Molecular Formula: --, Molecular Weight: --, HS Code ---**

How big is your requirement or how small
We serve it all.

Specifications, Safety Data Sheet, Manufacturing process details, Wholesale retail buy sell prices, Uses etc available on line in these pages for Aluminum Silicate or Magnesium Aluminum Metasilicate.

For SDS MSDS Sheet Click
SDS MSDS Sheet of Magnesium Aluminum Silicate or Magnesium Aluminum Metasilicate USP Manufacturers

Spanish Silicato de magnesio y aluminio o metasilicato de magnesio y aluminio

Portuguese Silicato de Alumínio e Magnésio ou Metasilicato de Alumínio e Magnésio

Magnesium Aluminum Silicate
Magnesium Aluminum Metasilicate Pure USP NF Grade Suppliers
Magnesium aluminum silicate

Magnesium Aluminum Silicate USP NF Grade
Magnesium Aluminum Silicate is a blend of colloidal montmorillonite and saponite that has been processed to remove grit and non-swellable ore components.
The requirements for viscosity and ratio of aluminum content to magnesium content differ for the several types of Magnesium Aluminum Silicate, as set forth in the accompanying table.

Type Viscosity(cps) (Al content)/(Mg content)
  Minimum - to - Maxamum Minimum - to - Maxamum
IA 0225 - to - 0600 0.5 - to - 1.2
IB 0150 - to - 0450 0.5 - to - 1.2
IC 0800 - to - 2200 0.5 - to - 1.2
IIA 0100 - to - 0300 1.4 - to - 2.8

Labeling: Label it to indicate its type.
Identification: Add 2 g in small portions to 100 mL of water, with intense agitation. Allow to stand for 12 hours to ensure complete hydration. Place 2 mL of the resulting mixture on a suitable glass slide, and allow to air-dry at room temperature to produce an oriented film. Place the slide in a vacuum desiccator over a free surface of ethylene glycol. Evacuate the desiccator, and close the stopcock so that the ethylene glycol saturates the desiccator chamber. Allow to stand for 12 hours. Record the Xray diffraction pattern, and calculate the d values: the largest peak corresponds to a d value between 15.0 and 17.2 angstrom units. Prepare a random powder specimen of Magnesium Aluminum Silicate, record the X-ray diffraction pattern, and determine the d values in the region between 1.48 and 1.54 angstrom units: peaks are found between 1.492 and 1.504 angstrom units and between 1.510 and 1.540 angstrom units.
Viscosity: After determining the Loss on drying, weigh a quantity of Magnesium Aluminum Silicate test specimen equivalent to 25.0 g on the dried basis. Over a period of a few seconds, transfer the un-dried test specimen to a suitable 1-L blender jar containing an amount of water, maintained at a temperature of 25 ± 2 , that is sufficient to produce a mixture weighing 500 g. Blend for 3 minutes, accurately timed, at 14,000 to 15,000 rpm (high speed). [NOTE—Heat generated during blending causes a temperature rise to above 30 .] Transfer the contents of the blender to a 600-mL beaker, allow to stand for 5 minutes, and adjust, if necessary, to a temperature of 33 ± 3 . Using a suitable rotational viscosimeter equipped with a spindle as specified below, operate the viscosimeter at 60 rpm for 6 minutes, accurately timed, and record the scale reading. For Type IA, use a spindle having a cylinder 1.87 cm in diameter and 0.69 cm high attached to a shaft 0.32 cm in diameter, the distance from the top of the cylinder to the lower tip of the shaft being 2.54 cm, and the immersion depth being 5.00 cm (No. 2 spindle); if the scale reading is greater than 90% of full-scale, repeat the measurement, using a spindle similar to the No. 2 spindle but having the cylinder 1.27 cm in diameter and 0.16 cm high instead (No. 3 spindle). For Type IC, use a No. 3 spindle; if the scale reading is greater than 90% of full-scale, repeat the measurement using a spindle consisting of a cylindrical shaft 0.32 cm in diameter and having an immersion depth of 4.05 cm (No. 4 spindle). For Types IB and IIA, use a No. 2 spindle.
Microbial limits: Its total aerobic microbial count does not exceed 1000 cfu per g, and it meets the requirements of the test for absence of Escherichia coli.
pH: between 9.0 and 10.0, in a suspension (5 in 100) in water.
Loss on drying: Dry it at 110C to constant weight: it loses not more than 8.0% of its weight.
Acid demand: After determining the Loss on drying, weigh a quantity of Magnesium Aluminum Silicate equivalent to 5.00 g, and disperse in 500 mL of water with the aid of a suitable blender fitted with a 1-liter jar. Using a stopwatch, designate zero time. With constant mixing, add 3.0-mL portions of 0.100 N hydrochloric acid at 5, 65, 125, 185, 245, 305, 365, 425, 485, 545, 605, 665, and 725 seconds, and add a 1.0-mL portion at 785 seconds. Determine the pH potentiometrically at 840 seconds: the pH is not more than 4.0.
Arsenic: The limit is 3 ppm.
Lead: To pass the test The absorbance of the Test preparation is not greater than that of the Standard preparation (0.0015%).
Assay for aluminum and magnesium content: To pass the test.

We also offer Aluminium Magnesium Silicate BP Grade

For Original Monographs of IP Indian Pharmacopoeia BP British Pharmacopoeia USP US Pharmacopoeia FCC Food Grade product, please check with the respective web-pages or books.

We manufacture and supply as under:

Magnesium Acetate

Magnesium Aluminometasilicate

Magnesium Aluminum Silicate

Magnesium Butyrate

Magnesium Citrate

Magnesium Chloride Hexahydrate & Anhydrous

Magnesium Glycerophosphate

Magnesium Pidolate

Magnesium Peroxide

Magnesium Sulfate Hepta & Anhydrous

Magnesium Trisilicate.

We also manufacture and supply as under:

Aluminum Acetotartrate

Aluminum Gluconate

Aluminum Lactate

Aluminium Magnesium Silicate

Aluminium Silicate

Fumed Silica & Precipitated Silica

Hydrated Calcium Silicate

Sodium Aluminosilicate.

Manufacturers:

MUBY CHEMICALS
Ambernath Mumbai, Ankleshwar Gujarat, India
TEL: (OFFICE) +912223770100, +912223726950
Current Date Time in India GMT+5:30

e-mail: info@mubychem.com

USA, Canada, Mexico and other American
neighbouring buyers may
e-mail: us@mubychem.com
Call toll-free 1-877-682-9243 (1-877-MUBYCHEM)

Manufacturers india
Copyright and Usual Disclaimer is Applicable.
Last 12 March, 2024

Exporter & Importer By Air Exports Exporters & Improters Magnesium aluminum silicate manufacturers

Exporters to USA Canada UAE Europe South Africa Tanzania Kenya Uganda Egypt Nigeria Turkey Mexico Brazil Argentina Chile Dubai etc.

Global or International Suppliers, Exporters, Importers, Manufacturers

I shall pass through this world, but once. If therefore, there is any good that I can do, or if there is any favor that I can show to a fellow human being, let me do it now. Let me not defer or neglect it. For I shall not tread this way again

Magnesium Aluminum Silicate SDS, Safety Data Sheet
MSDS Sheet, Material Safety Data Sheet
26-Oct-20

Section 1: Chemical Product and Company Identification

Product Name & Other Names: Magnesium Aluminum Silicate or Aluminum Magnesium Silicate.
CAS Number
: 1327-43-1 or 12199-37-0 also 12511-31-8 or 12174-11-7.
EINECS EC Code: 215-478-8
Chemical Formula: AlMgO4Si
Molecular Weight: 143.37
Relevant uses and uses advised against (if any): Industrial Manufacturing.
Suppliers: As per letterhead.

Section 2: Hazards Identification

GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Classification according to Regulation (EC) No 1272/2008

Not a hazardous substance or mixture according to Regulation (EC) No. 1272/2008.
This substance is not classified as dangerous according to Directive 67/548/EEC.

Labeling according GHS & Regulation (EC) No 1272/2008

GHS Label Elements
NONE

Signal Word: None

Hazards not otherwise classified (HNOC):
May causes mild skin irritation.
May causes mild eye irritation.

Precautionary statements:
P261: Avoid breathing dust/fume/gas/mist/vapors/spray.
P262: Do not get in eyes, on skin, or on clothing.
P281: Use personal protective equipment as required.
P302+P352 - IF ON SKIN: Wash with plenty of soap and water.
P304 + P340 - IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Section 3: Composition and Information on Ingredients

Product Name & Other Names: Magnesium Aluminum Silicate or Aluminum Magnesium Silicate.
CAS Number
: 1327-43-1 or 12199-37-0 also 12511-31-8 or 12174-11-7.
EINECS EC Code: 215-478-8

Section 4: First Aid Measures

Always seek medical advice after the first aid treatment.

Skin: Rinse with water. Soap may be used. Seek Medical Aid.
Eyes: Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally. Seek Medical Aid.
Inhalation: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.
Ingestion: If swallowed, induce vomiting immediately after giving two glasses of water. Never give anything by mouth to an unconscious person.
Notes to Physician: Treat symptomatically.

Section 5: Fire and Explosion Data

Flammability of the Product: Non-flammable.
Auto-Ignition Temperature: Not applicable.
Flash Points: Not applicable.
Flammable Limits: Not applicable.
Products of Combustion: Aluminum oxide, Magnesium oxide, Silicon oxides.
Fire Fighting Media and Instructions: Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At high temperatures under fire conditions, it may produce toxic or irritating fumes. Fire-extinguishing work is done from the windward and the suitable fire-extinguishing method according to the surrounding situation is used. Uninvolved persons should evacuate to a safe place.

Section 6: Accidental Release Measures

Personal precautions, protective equipment, and emergency procedures: Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Restrict unprotected personnel from the area. Prevent any contact with hot surfaces. Do not approach facing the wind. Do not touch the spilled material. Keep away from incompatibles such as oxidizing agents, acids.
Environmental precautions: Do not let the product enter drains, soil or water sources.
Methods and materials used for containment Cleanup procedures and Storage:
Small Spill: Use appropriate tools to put the spilled solid in a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and dispose of according to legal requirements.
Large Spill: Contain spilled material. Do not inhale vapors, dust, mist, or gas. Avoid dust formation. Use a shovel to put the material into a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and allow to evacuate as per law.

Section 7: Handling and Storage

Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid contact with skin, eyes, and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Avoid ingestion and inhalation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Prevent any contact with hot surfaces.
Conditions for safe storage, including any incompatibilities: Store in cool, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Do not leave the material container open. Store protected from heat, sparks and ignition sources and incompatible materials. Avoid contact with skin and eyes. Avoid inhalation of dust/mist/vapor. Do not store with incompatible materials like oxidizing agents, acids.

Section 8: Exposure Controls/Personal Protection

Engineering Controls: Use process enclosures, local exhaust ventilation, or other engineering controls to keep airborne levels below recommended exposure limits. If user operations generate dust, fume, or mist, use ventilation to keep exposure to airborne contaminants below the exposure limit.
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator may be worn. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Dust deposits on floors and other surfaces may pick up moisture and cause the surfaces to become slippery and present safety hazards. Handle in accordance with good industrial hygiene and safety practice. Wash hands after handling.

Section 9: Physical and Chemical Properties

Physical state and appearance: Solid white to off-white powder or granules.
Odor: Odorless.
Odor threshold: Not available.
pH: Not available.
Specific Gravity: 2.6
Melting point/freezing point: Not available.
Initial boiling point and boiling range: Not available.
Flash point: Not available.
Auto-ignition temperature: Not available.
Decomposition temperature: Not available.
Upper/lower flammability or explosive limits: Not available.
Vapor pressure: Not available.
Vapor density: Not available.
Evaporation rate: Not available.
Flammability (solid, gas): Not available.
Partition coefficient: n-octanol/water: Not available.
Solubility: Insoluble in cold water.
Viscosity: Not available.
Chemical Formula: AlMgO4Si
Molecular Weight: 143.37

Section 10: Stability and Reactivity Data

Stability: It is stable in room temperature in closed containers under normal storage & handling.
Conditions of instability: Incompatible materials
Incompatibility with various substances: Strong oxidizing agents.
Polymerization: Will not occur.

Section 11: Toxicological Information

Toxicity to Animals: LD50/oral/rat = > 16000 mg/kg Oral LD50 Rat.
Carcinogenic Effects: Not a reported carcinogen by IARC, NTP, ACGIH, OSHA.
Reproductive Effects: No information available
Developmental Effects: No information available.

Section 12: Ecological Information

Ecotoxicity: No specific data or information available regarding environmental impact.
Persistence and Degradability: No information available.
Mobility: No information available.
Bioaccumulation/ Accumulation: No information available.
Results of PBT and vPvB assessment: No data available for assessment.

Section 13: Disposal Considerations

Waste Disposal: Waste must be disposed of in accordance with federal, state, and local environmental control regulations.

Section 14: Transport Information

DOT USA, TDG Canada & ADR/RID Europe: Not dangerous goods
IMDG/IMO: Not dangerous goods
IATA: Not dangerous goods.

Section 15: Other Regulatory Information

USA Federal and State Regulations:
California Prop. 65 Components: This product does not contain any chemicals known to State of California to cause cancer, birth defects, or any other reproductive harm.
Section 302 Extremely Hazardous Substances and TPQs: None
Section 313 Chemical Category: None

Section 16 - Additional Information

Disclaimer:
**************************
Our company provides this MSDS sheet in good faith but makes no representation as to its comprehensiveness or accuracy. This SDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. The above information has been compiled from various sources and has the possibility of discrepancy and being out-dated information. Individuals receiving the information must exercise their independent judgment and do further search in determining its appropriateness for a particular purpose. In no case shall our company be liable to loss or damages by the product user.
**************************